GE Security ZP3 Manual Online: Planner, Level 4 Operations, Table 24: Planner. Menus, or it can be done off-line on a PC, using Ziton Planner software,.
• ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual P/N 503-1160ZE-I-12 • REV 12.0 • ISS 13SEP11. • © 2011 UTC Fire & Security. All rights reserved. The ZP3 name and logo are trademarks of UTC Fire & Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
• EN 54 Setup requirements 101 Introduction 106 Verification 106 System tests 108 Introduction 112 Peer-to-peer 3 (P2P3) protocol 112 Panel filters set, store and send capability 114 New network filters 114 Language loading 116 ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual. • Introduction 118 System cabling 120 Z-Address lines 121 Serial communication lines 128 DC control lines 130 Overview 132 Routine maintenance 132 Maintenance menu 135 Interpretation of analogue readings 143 Corrective maintenance 150 ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual. • Trained service personnel must carry out procedures in this manual. The ZP3 panel is powered from a 230 VAC primary supply and from a 24 VDC battery backup supply. The power supply forms part of the main board assembly.
This assembly consists of a circuit board (incorporating the power supply), mounted on a metal chassis, with the power supply covered by a metal enclosure. • The backup batteries contain substances that are potentially hazardous to your health and to the environment. ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual. • 8.9 Output to fault warning routing equipment (output to J) 9.5 Disablement of addressable points Test conditions 10.1 General requirements 10.2 Indication of the test condition 10.3 Indication of zones in the test state Standardized input/output interface ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual. Crack serial keygen. • ZP3AB-NET1 Network Board Installation Sheet 501-0485ZE-1-01 ZP3AB-SCB-D Serial Display Unit Interface Installation Sheet 501-0482ZE-1-01 Planner User Guide 503-1436ZE-U-06 European Standard EN 54 (Parts 2 and 4) British Standards BS 5839 (Part 1: 1988) ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual. • Display and controls 10 Panel construction 10 Built-in communication port 16 Optional modules 19 Communication boards 19 Remote display unit 25 Accessory plate 25 Modem 28 Printer 31 Quick start 34 ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual. • Chapter 1: Installation overview The ZP3 fire control panel (see Figure 1) is a state-of-the-art analogue addressable panel that complies with EN 54 parts 2 and 4.
It is a compact microprocessor controlled unit, of modular design. Hardware and software modules enable you to configure virtually any system requirement. • Chapter 1: Installation overview Refer to Table 4 below for detailed specifications for the ZP3 Fire Control Panel. Fire alarm panel Complies with European Standard EN 54-2 Power supply Complies with European Standard EN 54-4 Electromagnetic CE Marked. Complies with European Directive 89/336/EEC. • Panel (alarm at 24 VDC) 500 mA Load of panel only, excluding any external devices Per Loop (quiescent at 24 150 mA Fully loaded loop, with 127 ZP VDC) devices, not in alarm ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual. • For connection to fault alarm RMC routing equipment Zone walk test EN 54-2 One-man test of a zone, other zones remain working Control outputs EN 54-2 Up to 768 programmable control outputs ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual.
• Scroll events (more) Button Manually scrolls the list of alarms on LCD screen Controls ON/OFF Key switch Enables or disables front panel controls Operator menu/keypad Keypad For operator, maintenance, and setup menus ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual. • Voltage-free relay contacts, common to fault alarms Remote manned centre (fire) Monitored voltage output to RMC transmitter for fire Remote manned centre (fault) Monitored voltage output to RMC transmitter for fault ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual. • [5] In a fire alarm condition, the battery charging is disconnected. Therefore, in a fire condition, additional current is available for external fire alarm devices only, such as sounders. ZP3 Fire Control Panel Installation, Commissioning, and Maintenance Manual. • Chapter 1: Installation overview See Figure 2 for the dimensions of the ZP3 fire alarm panel. The basic panel is designed for surface mounting, and flush-mounting kits are available.